Autor |
Nachricht |
Forum: OBD Thema: Webasto Thermo Top C - KKL Interface (USB) |
Luc |
Verfasst: Freitag 10. Dezember 2010, 13:45
|
|
Antworten: 21 Zugriffe: 101152
|
webasto geht super mit KKL.
as said above 1800 baud 1 ms bmm waiting time and make sure that your kkl is ok. I had some problems with my FT232BL after reinstalling him i had no more problems.
If you have more questions i can make some pictures and snapshots of my setup.
Luc |
|
 |
Forum: OBD Thema: kkl + webasto 24 volt ? |
Luc |
Verfasst: Mittwoch 1. Dezember 2010, 20:41
|
|
Antworten: 4 Zugriffe: 16419
|
just connected my new kkl with 1 k resistors to my airtop 2000 st 24 volt, works perfect !!
tnx
luc |
|
 |
Forum: OBD Thema: kkl + webasto 24 volt ? |
Luc |
Verfasst: Dienstag 23. November 2010, 21:16
|
|
Antworten: 4 Zugriffe: 16419
|
I just measured on the webasto airtop , pin 5 of x 6 (w bus) gives 23 volt DC, can the kkl handle this voltage you think ? or should the voltage of the bus be the same as the VB+ ? As i can see in the sheet of the l9637 it should not be a problem ( but i toasted one over here so there is somethink s... |
|
 |
Forum: OBD Thema: kkl + webasto 24 volt ? |
Luc |
Verfasst: Dienstag 23. November 2010, 13:23
|
|
Antworten: 4 Zugriffe: 16419
|
Hello,
A couple of questions from a newbe : If my unit ( airtop 2000st ) is 24 volt is the W bus also 24 volt ? high state is 24 volt ? If i change the 510 ohms(r4 / r6 ) on my interface does this mean i can use 24 volt as main power os is this just for wbus ?